Explosion Proof In-line Hydrogen Process Analyzer H2scan’s HY-OPTIMA? 2700 series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA? 2700 series is an explosion proof device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 60oC. The HY-OPTIMA? 2700 series is ideal for process gas applications where real time continuous measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.
Verification Interval: 90 days
Product Life Expectancy: 10 Years
Pressure Compensation: Yes
Operating Humidity: < 95% RH (non condensing)
Flow Rate: 0.1 to 10 slpm
Process Gas Temperature: -20°C to 60°C
Operating Temperature-20°C to 55°C
Storage Temperature -30°C to 80°C
Output Signals
Analog: 4 to 20mA (or user specific mA)
Serial: RS422 or TS422
Relay Contacts2: 5A/240 VAC or 5A/30 VDC
Input Voltage: 90-240 VAC
Input Power: 15W
Dimensions: 7.5in (L) x 5.4in (W) x 5.7in (D)
Adapter Fitting: 3/4 in Union Tee Compression
1. ATEX versions are limited to 1.1 ATM max process gas pressure
2. Two programmable relays and one fault relay with normally open (N.O.) and normally closed (N.C.) contacts
The HY-OPTIMA? 2700 Series inline hydrogen process analyzer is ideal for gas streams where real-time,
hydrogen-specific measurements can enhance process plant efficiencies, improve yields, and reduce maintenance costs:
Refinery
?Catalytic reforming
?Hydrodesulphurization
?Fuel gas
?Tail gas treating units
Natural Gas
?H2 measurement in polymer feeds and flare gas process streams
Manufacturing
?Metals annealing
?Semiconductors
?Oil hydrogenation
?
Performance | ||
Operating Pressure at Analyzer: | ||
Recommended: | 0.95 – 1.1 atm absolute (14.0 – 16.1 psia) | |
Maximum: | 2 atm absolute (29.4 psia) | |
Note: Analyzers are factory calibrated at 1 atm. For operation at higher pressure special factory calibration is required which may incur a nominal fee. | ||
Process Gas Temperature: | -20 to 60°C | |
Flow Rate: | 0.1 to 10 slpm | |
Operating Humidity: | < 95% RH (non- condensing) | |
Calibration Interval: | 90 days | |
Output Signals | ||
Analog: 4-20 mA | Serial: RS232 or RS422 | |
Relays: 5A/240 VAC or 5A/30 VDC | ||
Two programmable relays and one fault relay | ||
Power | ||
Input Voltage | Input Power | |
90 – 240 VAC, 50 – 60 Hz | 15 W | |
Physical | ||
Dimensions | Weight | |
7.5in (L) x 5.4in (W) x 5.7in(D) | 5.9 lbs | |
Adapter Fitting: ? Inch Union Compression Tee | ||
Environmental | ||
Operating temp: -20 to 55°C | Storage temp: -30 to 80°C | |
Ingress Protection: IP67 |