激情 小说 亚洲 图片 伦,国产99久久久国产精品免费看,88国产精品欧美一区二区三区,擦老太BBB擦BBB擦BBB擦

400 086 1088

CN

高精度動態(tài)配氣儀-Zephyr

On-site customized Gas Standard Preparation has never been easier than with Zephyr, the down sized version of GasMix?. The 5’’ touch screen allows the control of two mass flow controllers in order to create gas standards from a concentrated gas and a diluent. These mixtures and dilutions can be programed into sequences which may be used for a wide variety of applications like analyzer calibration, glove box atmosphere control, sample steam dilution and/or internal standard addition.

 Ease to Use

● Resourceful and Transportable

● Reduced Operator Time

● Calibration Curves for each used gas

● Gas feeds and outlet are customizable


AlyTech GasMix? Software

The dedicated Software ZeSoft is fully automated and allows a single injection run or a reprogrammed sequence.Uncertainty of the final gas concentration is calculated taking into account the used flow and the concentration uncertainty of the parent gas. The software can communicate with any analyzer linked to Zephyr via contact closure.

E.g.: drive an external injection valve / launch an analysis with external Start.

Ten different sequences can be saved and recall at any time.

NEW : Smart Sequence building---User chooses the number of points, starting and ending concentration values, and the software calculates the respective concentration levels.

Feature

? Linearity check and calibration of GC with FID, TCD, PID, PHID,

SCD, MS and other detectors

? Calibration of gas analysers for refinery process control

? Linearity check and calibration of trace elemental analysers

? Validation / calibration of microGC for biogas characterisation

? Creation of controlled atmosphere in reactors for aging or

oxidation

? And much more applications

?? Number of gas channels: 2

?? Inlet Gas Pressure: 3 bars nominal, max 8 bars

?? Outlet Pressure: atmospheric, higher on request

?? Connections: Swagelok 1/8” ,other on request

?? Gas compatibility: In standard with Kalrez seals,

stainless steel 316 tubing with inert coating.

Compatible with most aggressive gases and active

compounds like trace sulfurs, NO2, ammonia, VOC (for

specific cases, please contact us)

?? Dilution ratio of the initial concentration: 1:2000 in

standard /up to 10000 max

??MFC operation range: 2 to 100% FS

?? Flow accuracy: ±1% of setpoint all over the scale

?? Repeatability: less than 0.1% of setpoint

?? Response time to the setpoint <5 sec

?? 5” Color touch screen

?? Embedded dedicated ZeSoft software

?? Power supply: 90-260Vac, 1,5-4A, 50-60Hz

?? Optional: NiCad rechargeable battery autonomy 8h

?? Operation temperature: 10-50°C

?? Dimensions : L x l x h (cm) : 38 x 16 x 26; Weight: 6,5kg

* Note: Specifications subject to change without notice